Power Systems Specialists, Inc.
Call Toll Free (888) 305-1555

Toshiba Mitsubishi Chloride Datron
UPS Systems G9000 Series 3 Phase
Toshiba G9000 Series 3 Phase UPS

80-750kVA

The G9000 series UPS is available in capacities of 80, 100, 160,  225, 300, 500, and 750 KVA and comes with an industry-leading three-year on site warranty. It is designed for stand-alone operation or as a parallel system with up to four-unit configurations. All without the requirement of special switchgear cabinet.

With Power Factory ratings of 0.9PF for the 80-225kVA size and 1.0PF for the 300-750kVA size the G9000 series has can provide the power that other competitor's units can not provide.

The G9000 Series incorporates the new Toshiba IGBT technology in the UPS. This IGBT technology is used in the rectifier/converter, DC/DC chopper, and the inverter sections of the UPS. By using this new IGBT technology the G9000's double-conversion topology provides an AC/DC/AC efficiency of 96.5% or greater at loads from 50% to 100%. Even at 20% loading, the efficiency remains greater than 94%. This is 10% to 20% better than current industry systems, making the G9000 excellent for N+1 parallel systems where system loads are typically 30-40% of system capacity.

These units will pave for themselves in energy savings in a relative short time as compared to our competitors models.

Click Here for the Full Brochure. (1MB)

G9000 Specifications
Model Number T90S3S08KS6XSN
T90S3S10KS6XSN
T90S3S16KS6XSN
T90S3S22KS6XSN
Capacity
kVA/kW
80 / 72
100 / 90
160 / 144
225 / 202.5
Topology
True On-Line, Double Conversion, Advanced Multi-Level IGBT Technology
Input Voltage
480 V, Three-Phase, Three-Wire + Ground/Bypass Input, 480 V, Three-Phase, Three-Wire + Ground
Voltage Range
480 V, -20% to +15% (384 to 552 V Without Utilizing Battery)
Power Factor
Greater than 0.99
Current THD
<3% at 100% Load (No Input Filter Required)
Frequency
60 Hz (± 10%)
Current Limit
125% Max
Output Voltage / THD
480 V, Three-Phase, Three-Wire + Ground
Frequency
60 Hz, ±0.01% (In Free-Running Mode)
Voltage Regulation
±1.0% (0.5% Typical)
Power Factor
0.9 Lagging
Power Factor Range
0.9 Lagging to 0.95 Leading
Voltage THD
<2% for Linear Load, <5% for Non-Linear Load
Overload (inverter)
125% for 2 Minutes; 150% for 60 Seconds
Overload (bypass)
1000% for One Cycle
Battery DC Link
480 V DC
Environment Temperature Range
32° to 104°F (0° to 40°C)
Relative Humidity
5% to 95% Non-Condensing
Heat Rejection
10,771 BTUs/Hour
13,463 BTUs/Hour
17,821 BTUs/Hour
25,060 BTUs/Hour
Efficiency (Full Load)
95.80%
95.80%
96.50%
96.50%
Efficiency (20% Load)
92.50%
92.50%
94.70%
94.90%
Altitude
7380 Feet Maximum Without Derating (2250 Meters)
Audible Noise
70 dBA at 1 Meter
Dimensions Dimensions (W x D x H)
27.6 x 32.8 x 80.6 in.
35.4 x 32.8 x 80.6 in.
Weight
855 lbs
855 lbs
31160 lbs
1230 lbs
Features
Digital Signal Processor (DSP) Control, Fully Digital IGBT Converter & Inverter, High Efficiency Over Wide Load Range,
Transformer-Less Design, N+1 and N+N (Up to Four in Parallel) Capability, Dual-Input Feed, Electronic Battery Isolation,
RS232 and Dry Contact Interface, Small Footprint, Lightweight Design
Standards
UL 1778, CUL, ISO9001, ISO14001, ANSI C62.41 (IEEE 587), FCC Class A, Article 47, Part 15.B
Warranty
Three Years Onsite (Optional Two Year Extended Warranty)
See Toshiba Warranty Policy for Full Details
Service
7x24 Technical Support 1-877-867-8773 (1-UPS-TOS-UPS3)
 

Home | Power Quality Products | Power Quality Services

Send e-mail to: webmaster@p-s-s.com with questions or comments about this web site. Copyright © 2002-2011 Power Systems Specialists, Inc.