UPS Systems 1600EP Series Single Phase
Toshiba 1600EP Series Single Phase UPS Single Phase 3.6, 5, 8, 10, 14, 18 kVA & Plus Models

1600 Series is single phase UPS, available in 3.6kVA, 6.0kVA, 8kVA, 10.0kVA, 12kVA, 14kVA & 18kVA. This series offers in tower design solution. As a double conversion on-line UPS, it is able to supply uninterrupted, clean single-phase power to your critical systems while keeping batteries charged continuously, even if the utility power fails. This 1600EP Series will provide you with an additional 20% Extra Power! From a name that is synonymous with quality. This system combines true on-line technology, state of the art electronics and the Toshiba name to offer a high reliability UPS.
Other features of the UPS include:

  • Hot Swappable Batteries
  • Hot Swappable Cooling Fans
  • Internal Isolation Transformer
  • Digital LCD Display
  • Wide Input Voltage Window
  • Wide Input Frequency Window
  • Input Power Factor greater than 0.95
  • Power Factor Correction
  • Output Power Factor 0.85
  • Optional Network Interface Card
  • Optional Environmental Monitoring Device

Click Here for the Full Brochure. (1MB)

1600 EP Series Specifications
Capacity 3.6kVA(3.06kW) 6kVA(5.1kW) 8kVA(6.8kW) 10kVA(8.5kW) 14kVA(11.9kW) 18kVA(15.3kW)
Topology True On-line, Double Conversion, IGBT Power Factor Corrected Input, & Internal Isolation Transformer
Certifications UL 1778, CUL, CE, FCC Class A, IEEE 587, ANSI / C62.41, ISO 9001, ISO 14001, NEMA / PE1-1993
Input Characteristics
Input Voltage
Single-Phase 208/240 Vac (3 Wire Input / L-L,G), 230 Vac (3 Wire Input / L, N, G), +10% -30%
Input Frequency
45 - 65 Hz (Auto-Sensing)
Input Power Factor
> 0.95 for all loads
Input Current THD
< 5% (Even for 100% Non-Linear Loads)
Battery Characteristics
Battery Type
Valve Regulated Lead Acid, Flame Retardant (9.0 Amp Hr)
Backup Time - Fully Charged at 0.85 Power Factor, 77deg. F
14 minutes
7 minutes
7 minutes
5 minutes
7 minutes
5 minutes
 
Approximately 30% More Runtime for Output Power Factor of 0.7 (Triple the Backup Time at 1/2 load)
Recharge Time
24 hr. (full), 12 hr. (90%)
DC Link
216 VDC
288 VDC
Output Characteristics
Output Voltage
Single Phase 240/208/120 Vac (4 Wire Output / L-L, N, G) 230 Vac (3 Wire Output L, N, G)
Output Voltage Regulation
+/- 3% Max., +/- 1% Typical
Output Frequency
50/60 Hz +/- 0.5Hz/1Hz/1.5Hz (Factory or Authorized Service Center selectable.)
Output Voltage THD
< 3% for linear load; 1% Typical
Common Mode Noise
< 0.5V Peak
Rated Load Power Factor
0.85 (0.6-1.0) lag
Efficiency (ac-dc-ac)
> than 85%
Rated Output Current @ 240V
15A
25A
33.3A
42A
58A
75A
Max. Peak Output Current
45A
75A
100A
126A
174A
225A
Overload Capacity
150% for 10 Seconds / 125% for 10 Minutes / 1000% for 1 cycle
Heat Generation (BTU/Hr)
1588
2610
3482
4352
6092
7832
Mechanical Design
Enclosure
Enclosure of Unit made from Steel which Complies with NEMA 1 and UL Type 1 Standard
Enclosure Dimensions
27.5" x 10" x 33"
28.25" x 13" x 33.5"
39.1" x 17.5" x 34.8"
Shipping Weight 365 lbs./166 kg 385 lbs./175 kg
490 lbs./222 kg
620 lbs./281 kg 750 lbs./340 kg
Battery Pack Size
5"H x 7.3"W x 18.2"D (6 Batteries of NPX-35 Per Pack)
Battery Pack Quantity
3
4
8
Options
RemotEye II®
SNMP & WEB Based Monitoring, Internal and External Modules Available.
Matching Battery Cabinet
Consult Factory
Internal / Ext. Maintenace Bypass
Consult Factory
Receptacle Panel & Line Cord
Consult Factory
Warranty 3 Years on Electronics (UPS) / 2 Years Full on Battery ( See Toshiba Warranty Policy for Full Details)
 