UPS Systems G8000MM Series (Parallel)
Toshiba G8000MM Series 3 Phase UPS (Parallel)

Toshiba introduces the G8000MM UPS to the Multi Module UPS Market. The G8000MM combines Toshiba reliability and performance with ultimate flexibility to meet the needs of growing businesses.

  • 100-750kVA (Parallel)
  • Upgrade from Single Module to Parallel Module Anytime
  • Eliminating Static Bypass Cabinet (Reduces Footprint)
  • .9 Output Power Factor
  • IGBT Converter Reduces Input Current Harmonics (THD), IGBT Inverter

Click Here for the Full Brochure. (1MB)

 

 

G8000MM Specifications
Model Number
T8MS3K10
KK6XSN
T8MS3K15 KK6XSN
T8MS3K22 KK6XSN
T8MS3K30 KK6XSN
T8MS3K37 KK6XSN
T8MS3K50 KK6XSN
T8MS3K62 KK6XSN
T8MS3K75 KK6XSN
Capacity
kVA/kW
100/80
150/120
225/180
300/270
375/338
500/450
625/562
750/675
Topology
True On-Line, Double Conversion
Input Voltage
AC Input: 480 V Three-Phase Three-Wire + Ground
Bypass Input: 480 V Three-Phase Four-Wire + Ground
Voltage Range
480 V +15% to -15% (408 to 552 V Without Utilizing Battery)
Power Factor
Greater than 0.98
Current THD
< 6% at 100% Load; 9% Maximum at 50% Load
Frequency
60Hz (±5%)
Walk-in
5 to 30 Seconds (Adjustable)
Output Voltage
480/277 V, Three-Phase Four-Wire + Ground
Frequency
60 Hz ±0.05% in Free-Running Mode
Voltage Regulation
±1%
Power Factor
0.8 Lagging
0.9 Lagging
Voltage THD
2% Maximum THD at 100% Linear Load
5% Maximum THD at 100% Non-Linear load
Transient Response
±2% Maximum THD at 100% Step Load
±1% Maximum at Loss/Return of AC Power
±5% Maximum at Load Transfer to/from Static Bypass
Transient Recovery
< 16.7 ms
Voltage Unbalance
1% Maximum at 100% Unbalanced Load
Phase Displacement
1° Maximum at 100% Load
Overload (Inverter)
125% for 10 Minutes; 150% for 1 Minute
Overload (System)
1000% for One Cycle
(Available with Bypass),
500% for One Cycle
(Available with Bypass)
Battery Type
Lead Acid (VRLA or Flooded)
Nominal Voltage
480 VDC
Minimum Voltage
400 VDC
Charge Current (ADC)
13
19.5
29.3
39
48.7
65
92.5
92.5
Number of Cells
240
Environment Cooling
Forced Air
Temperature Range
32° to 104°F (0° to 40°C) During Operating and Storage
Relative Humidity
5% to 95% Non-Condensing
Heat Rejection
(BTU/h)
18,353
26,465
44,105
60,894
76,117
96,271
120,339
144,407
Efficiency (100% load)
93.7%
93.5%
93.3%
93.8%
93.8%
94.1%
94.1%
94.1%
Altitude
Charge Current (ADC)
13
19.5
29.3
39
48.7
65
92.5
92.5
Dimensions Dimensions (L x W x H)
36.8"L x 31.5"W x 78.7"H
55.1"L x 31.5"W x 78.7"H
76.8"L x 35.4"W x 78.7H"
Weight
2200 lbs
2756 lbs
3307 lbs
4400 lbs
Altitude
0 to 9000 ft.
Audible Noise @ 1m
68 DBA
72 DBA
76 DBA
78 DBA
80 DBA
Dimensions Width
43.3 in.
47.2 in.
55.1 in.
76.8 in.
114.2 in.
129.9 in.
Depth
29.8 in.
37.7 in.
49.5 in.
Height
79.7 in.
Weight
2061 lbs.
2579 lbs.
3263 lbs.
4564 lbs.
4916 lbs.
6923 lbs.
9193 lbs.
Features
Dual-Input Feed
Output Unity Power Factor, RS232 and Dry Contact Interface, Single or Parallel Operation
Standards
UL1778, CUL, NEMA PE1, ISO9001, ANSI C62.41 (IEEE 587)
Warranty
Three-Year Warranty on UPS Electronics Standard, Up to Five Years Available;
Three-Year Warranty on Batteries with Startup Purchase; See Toshiba Warranty Policy for Full Details
Service
24-Hour, 365-Day Technical Support 1-877-867-8773
 