UPS Systems 7000 Series
7000 Series

Toshiba 7000 Series UPS feature high-performance Insulated Gate Bipolar Transistor (IGBT) devices for which Toshiba is proud to have the world's top share. Toshiba was the first in the industry to employ IGBT high-speed power elements in UPS. In the field of UPS, Toshiba applies advanced technologies that it has developed from years of experience and achievements. Toshiba 7000 Series utilizes

• A PWM Converter resulting in:
1. Clean input power, a
2 Input Power factor 1.0 control (input capacity is reduced compared with Thyristor Rectifier UPS)
3. Input current sine wave control

• And a PWM Inverter resulting in
1. Clean output power
2. Quick voltage control, even in the load changes abruptly by 100%
3. Cleaner sine-wave output voltage even when the load current is distorted
4. Powerful balance control function capable of handling a 100% unbalanced load The 7000 series also includes an easy-to-read operation panel consisting of a graphics panel and LCD display. Along with easy front display interface, you will also receive an IC Memory card which stores various digital and analog system data.

Specifications
Rated capacity (kVA)
50
75
100
150
200
250
300
400
500
AC input Rated voltage
200, 210, 220V or 380, 415, 480V ±10%
Rated frequency
50Hz or 60Hz:±5%
Number of phases/wires
3-phase/3-wire
Input power factor
More than 0.97
Current harmonic distortion
Total 3.0% maximum
AC output Rated voltage
200, 210, 220V or 380, 415, 480V
Rated frequency
50Hz or 60Hz
Number of phases/wires
3-phase/3-wire or 3-phase/4-wire
Rated load power factor
0.9 lagging (Note 1)
Voltage accuracy
±1%
Voltage regulation (Note 2)
Single unit: ±1% max (for 100% unbalanced load)
 
Parallel-connected system: ± 2% max (same as above)
Overload capacity
125% - 10min, 150% - 1min.
Voltage ajustment range
± 5%
Frequency regulation
± 0.01% (for asynchronous operation)
Transient voltage variation
>±2% (loss or retem of AC input)
>±5% (100% load step change)
>±5% (closing or opening of parallel connection)
>±5% (transfer from bypass to UPS)
Recovery time
50msec. maximum
Voltage distortion
Total: 2.5% maximum (linear load)
Total: 5.0% maximum (100% rectifier load)
Others Installation location Indoors (a place that is free from corrosive gases and dust)
Ambient temperature
0 to 40°C (Recommended range: 18 to 30°C)
Humidity
30 to 90% (no condensation)
Note 1: Power factors of 0.95, 0.85 and 0.8 lagging are also available.
Note 2: Voltage unbalance ratio = (voltage between each output line – calculated average value of output voltage)/(calculated average value of output voltage).
Load unbalance ratio = (max. load current – min. load current)/(calculated average value of load current)
 