The 4200FA Series is a State of the Art designed UPS to meet all customers needs. The newly designed 4200FA Series offers a number of options to satisfy your needs. The 4200FA Series has the largest input voltage/frequency window in the industry. This allows for the unit to be user friendly to the batteries, thus extending the life of battery. The front end IGBT design allows it to work optimally at 0-100% load with low less than 3% THD on the input. This allows for one to one sizing of the Generator. The 4200FA Series also offers a Standard Three Year Warranty. The CT models are designed for internal batteries and internal maintenance bypass design without the need for additional cabinets. The XT model allows for internal isolation transformers built in the cabinet. The XT is built for extreme conditions and a large variety of three phase voltage applications. 4200FA CT Characteristics:
• True On-Line Double Conversion
• Input Power Factor > 0.98
• Input Current < 3%
• Wide Input Voltage Window +10% to -30%
• Wide Input Frequency Window 45-65 Hz
• Electronic Power Factor Correction for 100% Generator Compatibility
• Complete Front Access for Installation and Service
• 100% Unbalanced Load Capability
• SNMP/Web-Based Monitoring
• Battery Friendly Charger Design
• Three Year Standard Warranty
• XT Series for Extreme Applications
• Internal Maintenance Bypass Switch
• Internal Isolation Transformer Option
• Multiple Three Phase Voltage Combinations
Click Here for the Full
Brochure. (1MB)
|
|
Model Number |
T42X3X150X
AMXN |
T42X3X250X
AMXN |
T42X3X300X
AMXN |
T42X3X500X
AMXN |
T42X3X800X
AXXN |
| Capacity |
kVA/kW |
15/12 |
25/20 |
30/24 |
50/40 |
80/64 |
| Topology |
True on-line, double conversion, IGBT PWM,
with active input power factor correction |
| Input |
Voltage |
208 V, 220 V, 240 V, 380 V, 415 V, 480
V, 600 V, 3 Phase, 3 w + Gnd |
| Voltage Range |
+10% to -30% / +20% to -30% online (without
utilizing battery) |
| Power Factor |
Greater than 0.99 |
| Current THD |
Less than 3% |
| Frequency |
50/60 Hz (range 45-65 Hz) |
| Current Limit |
115% maximum |
| Output |
Voltage |
208 V, 220 V, 240 V, 380 V, 415 V, 480
V, 600 V, 3 Phase, 4 w + Gnd
|
| Frequency |
50/60Hz ± 0.01% (can be used as
a frequency converter) |
| Voltage Regulation |
< 1% balanced, 100% load step / <2%
unbalanced, 100% load step |
| Overload (inverter) |
125% for 90 sec, 150% for 30 sec |
| Overload (bypass) |
125% for 10 min, 1,000% for 10 ms |
| Battery |
DC Link |
288 VDC |
| Ripple Voltage |
< .5% DC |
| Environment |
Temperature Range |
0 - 40° C (operating) / -20 - +50°C
(storage) |
| Relative Humidity |
0-95% non condensing |
| Heat Rejection |
5,733 BTUs |
7,600 BTUs |
9,100 BTUs |
17,737 BTUs |
24,270 BTUs |
| Efficiency |
AC/DC/AC 87.7%, DC/AC 90% |
AC/DC/AC 88.5% |
AC/DC/AC 90% |
| Dimensions |
Dimensions (L x D x H) |
20" x 36.3" x 59.8" |
35.4" x 37.6" x 59.8" |
44" x 31" x 74" |
| (1 / 2) transformer(s) |
UPS Weight (lb) |
1275 / 1475 |
1275 / 1475 |
1275/1475 |
1,581 / 1,941 |
2,450 |
| |
Altitude |
6,600ft (2000 m) (maximum without derating) |
| |
Audible Noise |
< 60 dBA at 1 meter |
<65 dBA at 1 meter |
<65 dBA at 1 meter |
| Features |
Internal make - before - break maintenance
bypass switch*, RS232 and dry contact interface |
| Options |
Dual input feed, air filters for door,
RemotEye II® |
| Standards |
UL 1778, cUL, NEC, ISO9001, ISO14001, ANSI
C62.41 (IEEE 587), NEMA PE1-1993 |
| Warranty |
(See Toshiba warranty policy for full details) |
| Service |
7 x 24 Technical Support 1-877-867-8773
(1-UPS-TOS-UPS3) |
| *Not available on 80 kVA |
|