Power Systems Specialists, Inc.
Call Toll Free (888) 305-1555

APC Mitsubishi Toshiba Chloride Datron
UPS Systems 1700 Series Single Phase
Toshiba 1700 Series Single Phase UPS Single Phase 1.5, 2, 2.4 kVA & Plus Models

700 Series is a single phase UPS, available in 1.5kVA, 2.0kVA and 2.4kVA. This series offers in tower and the rack mount design solutions. As a double conversion on-line UPS, it is able to supply uninterrupted, clean single-phase power to your critical systems while keeping batteries charged continuously, even if the utility power fails. Other features of the UPS include

• Auto-Restart and Cold Start features
• Programmable Load Shed Receptacle
• Intelligent Charger with Rapid Charge in only 3.5 hours to 90%
• Wide Input Voltage Window
• Wide Input Frequency Window
• Input Power Factor greater than 0.97
• Output Power Factor 0.70
• Optional Network Interface Card
• Optional Remote Contact Card
• Optional Environmental Monitoring Device

Click Here for the Full Brochure. (1MB)

1700 Series Specifications
Model Number   UF1A1A015C6 * UF1A1A020C6 UF1A1A024C6
Capacity   1500VA(1050W) 2000VA(1400W) 2400VA(1680W)
Topology True on-line, double conversi on, IGBT PWM, with input power factor correction
Input Input Voltage Single phase 120VAC, +20% to -50%
  Input Frequency 30 to 70 Hz (50/60 Hz selectable)
  Input Power Factor Approximately unity 1.0
Output Output Voltage Single phase 120VAC, +/- 3%, steady state
  Output Frequency 50/60 Hz (+/-0.5% in free run mode, line sync +/-3%)
  Output Wave Form Sine wave, zero transfer time
  Rated Load Power Factor 0.7
  Rated Output Current 12.5A 16.7A 20A
  Inverter Overload Capacity 125% for one minute, 150% for 30 seconds
  Crest Factor 2.5 at full load
Battery Module Model Number UF1-BC-087 12V-7Ah, flame retardant, sealed lead acid (VRLA)
  Battery Backup Time (full load) 13 minutes 10 minutes 7 minutes
  Configuration 2 strings @ 4 x 12 VDC (48VDC)
Transformer Modules (option) Input/Output Voltage Common Mode Noise 208/240V in, 240/120V out; 230V in, 230V out;120V in, 120V out < 0.5V Peak (Isolation Module)
Line Cord   5-20P 5-20P L5-30P
Receptacles   (5)5-15R (4)5-15R & (1)5-20R (4)5-15R & (1)5-20R
Environment Operating temperature 0 to 40 degrees C (32 to 104 degrees F)
  Altitude Up to 1000m (3000 ft) above sea level
  Efficiency AC/DC/AC > 86%
Warranty   3 Year on electronics / 2 Years full on Battery (see Toshiba warranty policy for full details)
* Built in Isolation transformer available in UF1A1A015C6T UPS model

 

 

Home | Power Quality Products | Power Quality Services

Send e-mail to: webmaster@p-s-s.com with questions or comments about this web site. Copyright © 2002-2006 Power Systems Specialists, Inc.