C&D Technologies Powercom Division engineers and markets fully integrated power systems which provide back-up battery power in the event of a primary power loss or interruption and can both monitor and rectify AC to DC current in telecommunications equipment.
2033C Brochure
(.pdf)
| Full IGBT Transistors - Excellent Performance Characteristics |
Mitsubishi Electric is the leading manufacturer of Insulated Gate Bipolar
Transistors (IGBT). Mitsubishi Electric utilizes IGBTs in the converter and
inverter sections of our 2033C Series UPS systems. These advanced high
performance transistors, provide a variety of intelligent features: Large
power capabilities High speed switching Low control power consumption. |
| Low Heat Loss /High Efficiency |
| Use of the IGBTs permits efficient high speed switching (16kHz or12kHz),
thus reducing heat dissipation in the UPS. (Higher efficiency means lower
cost per kilowatt to the customer.) |
| Internal Maintenance Bypass (in addition to Static bypass) |
| All 2033C Series UPS systems are equipped with an internal wrap around "Zero
Energy" maintenance bypass system for greater maintenance flexibility. |
| Superior Functions |
- Front access only
- Automatic restart after low battery inverter stop
- Automatic retransfer
- Converter walk-in function
- "Form A" dry contacts
- High tolerance for overload /overcurrent
- Battery current limit
|
| Extended Battery Life |
| Power draw from batteries during step load conditions is no longer required
with the IGBT in both the converter and the inverter. Other UPS systems
required assistance from batteries when the converter was unable to supply
the required current. This cycling of batteries causes shorter life.
Mitsubishi Electric IGBTs incorporate the latest technologies and provide
step load applications (0-100%) without the use of batteries, thus ensuring
maximum battery service life (i.e. lower lifetime cost of UPS system). |
| Touch screen display allows user to access |
-
Input
/Output voltage
- Input /Output current
- KW
- Frequency
- Battery information
- Charge voltage
- Discharge voltage
- Diagnostics
|
| Warranty |
Standard warranty is two years, including parts, labor and batteries.
(NOTE: All information subject to change without
prior notice.) |
| UPS Voltage Configurations |
 |
| Standard Features |
- IGBT (Converter / Inverter)
- UL1778 / cUL listed UL924 listed
- Zero energy MBS
- Conformally coated boards
(industrial environment)
- Front access only (Serviceability)
- "DiamondSense" battery self-test
|
| Operating Environment |
- Low acoustic noise
- Temperature: 0 ~ 40°C
- Relative humidity: 5 ~ 95%
(non-condensing)
- Altitude: 0-9,000 feet
(no derating)
|
| Options |
- Seismic bracing brackets
- 480V Input (external matching cabinet)
- Software (for specific O/S systems)
|
| AC Input Rating +15% ~ -25% |
- Power: Rated 1kVA : 1kW
Generator 208Y / 120 VAC THD (reflected current):
- 4% typical (100% load) 7% typical (50% load)
- 3-phase, 4-wire, plus ground
- Frequency: 60Hz (±5%)
- Surge withstand: Meets IEEE C62.41-1991
- EMI compatibility: FCC Title 47, Part 15 Subpart B
|
| AC Output Rating |
- 3-phase, 4-wire, plus ground 208Y / 120 VAC
- Output power factor rating: 0.8 ~ 1.0 Lag (within output kW rating)
- Frequency: 60Hz ± 0.01% (free running)
- Voltage accuracy: ± 1%
- Transient recovery time: 16.7ms
- Load unbalance: 100% ± 2% or less
- Step load change: 0 ~ 100% ± 3%
- Load/ Return of AC power: ± 1% (at 100% load)
- UPS load transfer, bypass: ± 3% (at 100% load)
- THD (Voltage): 2% (100 % linear load);
- 4% (100% non-linear load)
- Slew rate: 1, 2Hz / sec (selectable)
|
| Battery Included |
- All in one
- Reduced foot print
|
| Quiet Operation |
- 7.5-20kVA→55dB (A scale, 1m)
- 30-50kVA→59dB (A scale, 1m)
|
| Internal Maintenance |
Bypass (in addition to Static bypass) All 2033C Series UPS systems are
equipped with an internal wrap around "Zero Energy" maintenance bypass
system for greater maintenance flexibility. Superior Functions
- Front access only
- Automatic restart after low battery inverter stop
- Automatic retransfer
- Converter walk-in function
- "Form A" dry contacts
- High tolerance for overload/overcurrent
- Battery current limit
- Battery self test
|
| Touch screen display allows user to access |
- Input/Output voltage
- Input/Output current
- KW
- Frequency
- Battery information
- Charge voltage
- Discharge voltage
- Diagnostics
- Fault /Alarm history Software
- RS-232C serial interface (Standard)
- DiamondLink application software (Optional)
- Multilingual
- Paging, E-mail capability during power events
- SNMP interface (NETCOM)
|
| One-Line Diagram |
 |
| Software: What is DiamondLinkTM? |
DiamondLink is user-customizable power monitoring, management and shutdown
software, designed to provide information about the power condition of
the
UPS systems. |
| How does DiamondLink work? |
DiamondLink is designed to run on network server or workstations in any
office environment. The software will monitor the status of your UPS and,
when critical events occur, will perform a graceful unattended
shutdown. |
| Features |
- Automatic unattended shutdown.
- Color coded power event logging.
- Smart messages can be user defined.
- User defined actions for a specific list of power events.
- Built-in graphing routines allow customized graphs to be created on-line.
- DiamondLink can be used with all Mitsubishi single phase and three phase
products.
|
| Specifics |
- Power history graph
- Custom user defined events
- Data log viewer
- E-mail configurations
- E-mail options for power events
- Event action
- Events log file
- Modem alert operation
- Pager notification
- Paging option
|
| Supported Operating Systems |
- Microsoft Windows®
- Microsoft Windows NT
- Microsoft Windows 95
- Microsoft Windows 98
- Microsoft Windows 00
- OS/2
- Novel NetWare®
- SVR4
- SCO UNIX
- SCO XENIX
- SolarisT
- IBM® AIX®-RS6000T
- HP-UX
- SGI
- Digital UNIX
- RED HAT LINUX
|
|